You need to enable JavaScript to run this app.
优惠活动
大模型
产品
解决方案
定价
更多

NVMe固态硬盘SMART错误日志条目持续增加问题排查求助

NVMe固态硬盘SMART错误日志条目持续增加问题排查求助

我已经连续好几个月收到smart守护进程发来的关于NVMe磁盘的告警邮件,折腾了好久都没找到问题根源,实在没办法了来求助各位大佬!

先给大家看看收到的邮件内容:

I'm getting regular emails from the smart daemon about my NVMe disk.

SMART error (ErrorCount) detected on host: desk

This message was generated by the smartd daemon running on:

host name: [redacted]

DNS domain: [redacted]

The following warning/error was logged by the smartd daemon:

Device: /dev/nvme0, number of Error Log entries increased from 2519 to 2521

Device info:

KBG30ZMV256G TOSHIBA, S/N:X8OPD1PGP12P, FW:ADHA0101

For details see host's SYSLOG.

You can also use the smartctl utility for further investigation.

The original message about this issue was sent at Sat Oct 7 23:38:04 2023 EDT

Another message will be sent in 24 hours if the problem persists.

我尝试了不少命令排查,下面是相关的命令和输出:

1. smartctl -a /dev/nvme0 输出

$ sudo smartctl -a /dev/nvme0

smartctl 7.3 2022-02-28 r5338 [x86_64-linux-6.1.0-13-amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Number:                       KBG30ZMV256G TOSHIBA
Serial Number:                      X8OPD1PGP12P
Firmware Version:                   ADHA0101
PCI Vendor/Subsystem ID:            0x1179
IEEE OUI Identifier:                0x00080d
Controller ID:                      0
NVMe Version:                       1.2.1
Number of Namespaces:               1
Namespace 1 Size/Capacity:          256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size:     512
Namespace 1 IEEE EUI-64:            00080d 04004ad9aa
Local Time is:                      Sun Oct 15 17:53:35 2023 EDT
Firmware Updates (0x12):            1 Slot, no Reset required
Optional Admin Commands (0x0017):   Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0017):     Comp Wr_Unc DS_Mngmt Sav/Sel_Feat
Log Page Attributes (0x02):         Cmd_Eff_Lg
Maximum Data Transfer Size:         512 Pages
Warning  Comp. Temp. Threshold:     82 Celsius
Critical Comp. Temp. Threshold:     85 Celsius

Supported Power States
St Op     Max   Active     Idle   RL RT WL WT  Ent_Lat  Ex_Lat
 0 +     3.30W       -        -    0  0  0  0        0       0
 1 +     2.70W       -        -    1  1  1  1        0       0
 2 +     2.30W       -        -    2  2  2  2        0       0
 3 -   0.0500W       -        -    4  4  4  4     8000   32000
 4 -   0.0050W       -        -    4  4  4  4     8000   40000

Supported LBA Sizes (NSID 0x1)
Id Fmt  Data  Metadt  Rel_Perf
 0 -    4096       0         0
 1 +     512       0         3

=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

SMART/Health Information (NVMe Log 0x02)
Critical Warning:                   0x00
Temperature:                        31 Celsius
Available Spare:                    100%
Available Spare Threshold:          10%
Percentage Used:                    33%
Data Units Read:                    35,454,740 [18.1 TB]
Data Units Written:                 70,575,255 [36.1 TB]
Host Read Commands:                 306,457,518
Host Write Commands:                881,616,851
Controller Busy Time:               12,766
Power Cycles:                       342
Power On Hours:                     21,991
Unsafe Shutdowns:                   617
Media and Data Integrity Errors:    0
Error Information Log Entries:      2,528
Warning  Comp. Temperature Time:    0
Critical Comp. Temperature Time:    0
Temperature Sensor 1:               31 Celsius

Error Information (NVMe Log 0x01, 16 of 64 entries)
Num   ErrCount  SQId   CmdId  Status  PELoc          LBA  NSID    VS
 0       2528     0  0x301c  0xc002  0x000            -     4     -
 1       2527     0  0x201d  0xc004  0x028            -     1     -
 2       2526     0  0x101d  0xc004  0x028            -     1     -
 3       2525     0  0x6005  0xc002  0x000            -     4     -
 4       2524     0  0x6004  0xc004  0x028            -     1     -
 5       2523     0  0x5006  0xc004  0x028            -     1     -
 6       2522     0  0x1006  0xc005  0x028            -     1     -
 7       2521     0  0x4013  0xc005  0x028            -     0     -

2. 其他尝试的排查操作

  • 执行了 nvme error-log /dev/nvme0,输出内容已保存到 nvme.log 文件中
  • 执行了 nvme list,输出如下:
$ sudo ./nvme-cli-latest-x86_64.AppImage list

Node                  Generic               SN                   Model                                    Namespace  Usage                      Format           FW Rev
--------------------- --------------------- -------------------- ---------------------------------------- ---------- -------------------------- ---------------- --------
/dev/nvme0n1          /dev/ng0n1            X8OPD1PGP12P         KBG30ZMV256G TOSHIBA                     0x1        256.06  GB / 256.06  GB    512   B +  0 B   ADHA0101

现在完全摸不着头绪,想请教各位:这些持续增加的错误日志到底是什么原因导致的?会不会影响硬盘的使用寿命或者数据安全?有没有什么办法能解决这个问题?