If your <TARGET> tag lacks complete database attributes, don’t worry—Informatica’s export XML stores target connection details in related nodes, not always directly on the TARGET itself. Here are the most reliable ways to track down the target database name:
Check associated
<SESSION>nodes
Every ETL job’s session (the executable unit) links to the target connection. Look for<SESSION>tags in your XML, and check for attributes likeDBDNAME(directly gives the database name) orCONNECTION_NAME(points to a pre-defined connection). For example:<SESSION NAME="S_Load_GL_Lines_Target" DBDNAME="PROD_FINANCE" CONNECTION_NAME="Target_Oracle_Conn" OBJECTVERSION="1" ...>The
DBDNAMEhere is your target database.Locate
<CONNECTIONS>definitions
If you find aCONNECTION_NAMEin the session, search the XML for a<CONNECTIONS>tag with that name. This node will explicitly list the target database details:<CONNECTIONS NAME="Target_Oracle_Conn" DBDNAME="PROD_FINANCE" DATABASETYPE="Oracle" OWNERNAME="FIN_USER" ...>Look for
<TARGET_DEFINITION>nodes
Target tables often reference a formal target definition. Search for<TARGET_DEFINITION>tags that match your<TARGET>'sNAMEattribute. These definitions typically includeDBDNAMEandOWNERNAMEfor the target database:<TARGET_DEFINITION NAME="GL_LINES_TARGET" DBDNAME="PROD_FINANCE" OWNERNAME="FIN_USER" DATABASETYPE="Oracle" ...>Search all
DBDNAMEattributes
Do a full search of the XML for theDBDNAMEattribute (excluding your source database's value). The remainingDBDNAMEentries are likely tied to your target connection or definition.
A quick tip: Informatica's export XML is structured to link objects (mappings, sessions, connections) by name, so cross-referencing the <TARGET>'s name with related session/definition nodes will usually lead you to the database details.