建立Ignite Thick客户端连接集群时服务端抛出OutOfMemoryError异常
Ignite 厚客户端连接集群异常问题
问题场景
尝试使用 Ignite 厚客户端连接集群时,按现有配置接入会同时触发客户端、服务端两侧报错。客户端与服务端处于同一网络的独立主机,其中服务端运行在 Kubernetes 环境下。Thin Client 可正常接入集群执行查询,无任何异常。
两侧报错日志
客户端日志
24-Feb-2021 15:18:31.135 WARNING [tcp-client-disco-msg-worker-#4%igniteClientInstance%-#39%igniteClientInstance%] org.apache.ignite.logger.java.JavaLogger.warning Timed out waiting for message to be read (most probably, the reason is long GC pauses on remote node) [curTimeout=1000, rmtAddr=/XXX.XXX.XXX.XXX:yyyy, rmtPort=yyyy] 24-Feb-2021 15:18:31.137 WARNING [tcp-client-disco-msg-worker-#4%igniteClientInstance%-#39%igniteClientInstance%] org.apache.ignite.logger.java.JavaLogger.warning Failed to connect ...skipping...
服务端日志
[14:58:09,536][WARNING][jvm-pause-detector-worker][IgniteKernal] Possible too long JVM pause: 1037 milliseconds. [14:58:10,536][SEVERE][grid-nio-worker-client-listener-0-#31][ClientListenerProcessor] Failed to process selector key [ses=GridSelectorNioSessionImpl [worker=ByteBufferNioClientWorker [readBuf=java.nio.HeapByteBuffer[pos=4 lim=439 cap=8192], super=AbstractNioClientWorker [idx=0, bytesRcvd=0, bytesSent=0, bytesRcvd0=0, bytesSent0=0, select=true, super=GridWorker [name=grid-nio-worker-client-listener-0, igniteInstanceName=null, finished=false, heartbeatTs=1614178688450, hashCode=645844509, interrupted=false, runner=grid-nio-worker-client-listener-0-#31]]], writeBuf=null, readBuf=null, inRecovery=null, outRecovery=null, closeSocket=true, outboundMessagesQueueSizeMetric=null, super=GridNioSessionImpl [locAddr=/10.0.1.81:10800, rmtAddr=/10.0.0.229:37584, createTime=1614178688450, closeTime=0, bytesSent=0, bytesRcvd=439, bytesSent0=0, bytesRcvd0=439, sndSchedTime=1614178688450, lastSndTime=1614178688450, lastRcvTime=1614178688450, readsPaused=false, filterChain=FilterChain[filters=[GridNioAsyncNotifyFilter, GridNioCodecFilter [parser=ClientListenerBufferedParser, directMode=false]], accepted=true, markedForClose=false]]] java.lang.OutOfMemoryError: Java heap space at org.apache.ignite.internal.processors.odbc.ClientListenerNioServerBuffer.read(ClientListenerNioServerBuffer.java:81) at org.apache.ignite.internal.processors.odbc.ClientListenerBufferedParser.decode(ClientListenerBufferedParser.java:57) at org.apache.ignite.internal.processors.odbc.ClientListenerBufferedParser.decode(ClientListenerBufferedParser.java:39) at org.apache.ignite.internal.util.nio.GridNioCodecFilter.onMessageReceived(GridNioCodecFilter.java:113) at org.apache.ignite.internal.util.nio.GridNioFilterAdapter.proceedMessageReceived(GridNioFilterAdapter.java:109) at org.apache.ignite.internal.util.nio.GridNioServer$HeadFilter.onMessageReceived(GridNioServer.java:3704) at org.apache.ignite.internal.util.nio.GridNioFilterChain.onMessageReceived(GridNioFilterChain.java:175) at org.apache.ignite.internal.util.nio.GridNioServer$ByteBufferNioClientWorker.processRead(GridNioServer.java:1192) at org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.processSelectedKeysOptimized(GridNioServer.java:2478) at org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.bodyInternal(GridNioServer.java:2243) at org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.body(GridNioServer.java:1880) at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) at java.lang.Thread.run(Thread.java:748) [14:58:10,539][SEVERE][grid-nio-worker-client-listener-0-#31][ClientListenerProcessor] Closing NIO session because of unhandled exception. class org.apache.ignite.internal.util.nio.GridNioException: Java heap space at org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.processSelectedKeysOptimized(GridNioServer.java:2504) at org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.bodyInternal(GridNioServer.java:2243) at org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.body(GridNioServer.java:1880) at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) at java.lang.Thread.run(Thread.java:748) Caused by: java.lang.OutOfMemoryError: Java heap space at org.apache.ignite.internal.processors.odbc.ClientListenerNioServerBuffer.read(ClientListenerNioServerBuffer.java:81) at org.apache.ignite.internal.processors.odbc.ClientListenerBufferedParser.decode(ClientListenerBufferedParser.java:57) at org.apache.ignite.internal.processors.odbc.ClientListenerBufferedParser.decode(ClientListenerBufferedParser.java:39) at org.apache.ignite.internal.util.nio.GridNioCodecFilter.onMessageReceived(GridNioCodecFilter.java:113) at org.apache.ignite.internal.util.nio.GridNioFilterAdapter.proceedMessageReceived(GridNioFilterAdapter.java:109) at org.apache.ignite.internal.util.nio.GridNioServer$HeadFilter.onMessageReceived(GridNioServer.java:3704) at org.apache.ignite.internal.util.nio.GridNioFilterChain.onMessageReceived(GridNioFilterChain.java:175) at org.apache.ignite.internal.util.nio.GridNioServer$ByteBufferNioClientWorker.processRead(GridNioServer.java:1192) at org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.processSelectedKeysOptimized(GridNioServer.java:2478) ... 4 more [14:58:12,523][WARNING][grid-timeout-worker-#22][ClientListenerNioListener] Unable to perform handshake within timeout [timeout=10000, remoteAddr=/10.0.0.229:44098]
接入代码与配置
Thin Client 接入代码
ClientConfiguration cCfg = new ClientConfiguration(); cCfg.setAddresses("XXX.XXX.XXX.XXX:yyyy"); IgniteClient igniteC = Ignition.startClient(cCfg);
Thin Client 接入全程运行正常
Thick Client 接入代码
IgniteConfiguration cfg = (IgniteConfiguration)fsxmlac.getBean("igniteClient.cfg"); ignite = Ignition.start(cfg);
Thick Client XML 配置
<beans xmlns="http://www.springframework.org/schema/beans" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation=" http://www.springframework.org/schema/beans http://www.springframework.org/schema/beans/spring-beans.xsd"> <bean class="org.apache.ignite.configuration.IgniteConfiguration" id="igniteClient.cfg"> <property name="workDirectory" value="/ignite/work"/> <property name="clientMode" value="true" /> <property name="dataStorageConfiguration" ref="dataStorageConfiguration" /> <property name="igniteInstanceName" value="igniteClientInstance" /> <property name="peerClassLoadingEnabled" value="false" /> <property name="metricsLogFrequency" value="1000000" /> <property name="communicationSpi" ref="communicationSpi" /> <property name="discoverySpi" ref="discoverySpi" /> <property name="cacheConfiguration"> <bean class="org.apache.ignite.configuration.CacheConfiguration"> <property name="name" value="session-cache"/> <property name="cacheMode" value="PARTITIONED"/> <property name="backups" value="1"/> </bean> </property> </bean> <bean id="dataStorageConfiguration" class="org.apache.ignite.configuration.DataStorageConfiguration"> <property name="defaultDataRegionConfiguration"> <bean class="org.apache.ignite.configuration.DataRegionConfiguration"> <property name="persistenceEnabled" value="true"/> </bean> </property> <property name="walPath" value="/ignite/wal"/> <property name="walArchivePath" value="/ignite/walarchive"/> </bean> <bean id="communicationSpi" class="org.apache.ignite.spi.communication.tcp.TcpCommunicationSpi"> <property name="slowClientQueueLimit" value="1000" /> <property name="localPort" value="32609" /> </bean> <bean id="discoverySpi" class="org.apache.ignite.spi.discovery.tcp.TcpDiscoverySpi"> <property name="ackTimeout" value="1000"/> <property name="socketTimeout" value="2000"/> <property name="ipFinder" ref="ipFinder" /> </bean> <bean id="ipFinder" class="org.apache.ignite.spi.discovery.tcp.ipfinder.vm.TcpDiscoveryVmIpFinder"> <property name="shared" value="false" /> <property name="addresses"> <list> <value>XXX.XXX.XXX.XXX:yyyy</value> </list> </property> </bean> </beans>
问题根因
- 存在端口配置错配:Thin Client 监听
10800端口,使用二进制客户端协议;厚客户端的集群发现节点列表必须填写服务端的 Discovery 端口(默认47500),不能直接复用 Thin Client 端口。 - 当前配置将 Thin Client 端口
yyyy填入了厚客户端的TcpDiscoveryVmIpFinder地址列表,厚客户端发出的集群发现握手请求会直接打到 Thin Client 的监听端口上。 - 服务端的 Thin Client 协议解析器无法识别厚客户端发出的 Discovery 协议报文,解析时会尝试分配超大内存缓冲区,直接触发堆内存溢出,最终导致连接超时。
解决方法
- 调整厚客户端
TcpDiscoveryVmIpFinder的地址列表,将当前填写的 Thin Client 端口替换为服务端实际的 Discovery 端口,格式为服务端IP:Discovery端口,例如XXX.XXX.XXX.XXX:47500。 - 检查 Kubernetes 服务端口放通规则,确保对厚客户端开放 Discovery 端口(默认 47500)、Communication 端口(默认 47100)的访问权限,保证厚客户端可与这两个端口直连。
- 适当调大服务端JVM堆内存参数,避免连接高峰期出现堆溢出问题。
内容的提问来源于stack exchange,提问作者RichardFeynman
相关产品推荐