Flink 1.12.2流处理作业全部事件被判定为迟到丢弃问题排查求助
Flink事件时间窗口所有事件都被判定为迟到进入侧输出如何排查?
我的Flink流处理管道代码如下:
FlinkKafkaConsumerBase kafkaConsumer = new FlinkKafkaConsumer<>(topic, new DeserializationSchema(),props); kafkaSource = env.addSource(kafkaConsumer).filter(<>); WatermarkStrategy<GenericMetricV2> watermarkStrategy = WatermarkStrategy .<GenericMetricV2>forBoundedOutOfOrderness(Duration.ofSeconds(900)) .withTimestampAssigner((metric, timestamp) -> { logger.info("ETS: mts: {}, ts: {}", metric.metricPoint.timeInstant, timestamp); return metric.metricPoint.timeInstant; }); metricStream = kafkasource .process(<>).assignTimestampsAndWatermarks(watermarkStrategy) .transform("debugFilter", TypeInformation.of(<>), new StreamWatermarkDebugFilter<>("Op")) .filter(<>).map(<>).flatMap(<>).keyBy(<>) .window(TumblingEventTimeWindows.of(Time.seconds(300))) .allowedLateneess(Time.seconds(900)) .sideOutputLateData(lateOutputTag) .aggregate(AggregateFunction, ProcessWindowFunction) .addSink()
当前作业并行度为1,采用默认200ms的setAutowatermarkInterval配置,由于Flink 1.12版本默认采用事件时间语义,因此我未额外设置setStreamTimeCharacteristic参数。
通过StreamWatermarkDebugFilter的输出我可以看到水印在正常推进,但是所有事件都被标记为迟到,被收集到lateOutputTag中,相关日志如下:
2021-05-18 17:14:19,745 INFO - ETS: mts: 1621310100000, ts: 1621310582271 2021-05-18 17:14:19,745 INFO - ETS: mts: 1621310100000, ts: 1621310582271 2021-05-18 17:14:19,842 INFO StreamWatermarkDebugFilter - Op, Watermark: 1621309499999 2021-05-18 17:14:19,944 INFO - ETS: mts: 1621309800000, ts: 1621310582275 2021-05-18 17:14:19,944 INFO - ETS: mts: 1621309800000, ts: 1621310582275 ... 2021-05-18 17:14:20,107 INFO - ETS: mts: 1621310380000, ts: 1621310582278 2021-05-18 17:14:20,107 INFO - ETS: mts: 1621310380000, ts: 1621310582278 2021-05-18 17:14:20,137 INFO StreamWatermarkDebugFilter - Op, Watermark: 1621309779999 2021-05-18 17:14:20,203 INFO - ETS: mts: 1621309800000, ts: 1621310582279 ... 2021-05-18 17:17:47,839 INFO - ETS: mts: 1621310100000, ts: 1621310681159 2021-05-18 17:17:47,848 INFO StreamWatermarkDebugFilter - Op, Watermark: 1621310099999 2021-05-18 17:17:47,958 INFO - ETS: mts: 1621309800000, ts: 1621310681237 2021-05-18 17:17:47,958 INFO - ETS: mts: 1621309800000, ts: 1621310681237 ... 2021-05-18 17:22:24,207 INFO - ETS: mts: 1621310100000, ts: 1621310703622 2021-05-18 17:22:24,229 INFO StreamWatermarkDebugFilter - Op, Watermark: 1621310399999 2021-05-18 17:22:24,315 INFO - ETS: mts: 1621309800000, ts: 1621310705177 2021-05-18 17:22:24,315 INFO - ETS: mts: 1621309800000, ts: 1621310705177
我已经确认不是数据源空闲导致的问题,请问该如何进一步排查定位该问题的根因?
排查方案
- 优先检查配置拼写错误
你代码中的allowedLateneess拼写错误,Flink官方正确的方法名是allowedLateness,拼写错误会导致允许迟到的配置不生效,默认允许迟到时间为0,只要水印超过窗口结束时间,后续到达的事件都会直接被判定为迟到进入侧输出,这是最高概率的根因。 - 验证流引用是否正确
你代码中定义的源变量是kafkaSource(大写S),但后续构造metricStream时用的是kafkasource(小写s),如果实际代码中这是两个不同的流对象,那么你配置的水印策略根本没有应用到窗口所在的流上,会导致窗口算子拿到的水印不符合预期。 - 校验窗口关闭阈值匹配逻辑
你使用的是5分钟滚动事件时间窗口,允许迟到15分钟,单个窗口的关闭阈值为窗口结束时间 + 15分钟,你可以在窗口算子前新增日志,打印每个事件的时间戳、所属窗口的起止时间、窗口关闭阈值,同时打印当前算子收到的水印,只要水印超过窗口关闭阈值,事件就会被判定为迟到,对比数值即可确认逻辑是否符合预期。 - 排查水印传递链路是否正常
你当前的水印debug日志是在水位线生成后直接打印的,如果后续的process/filter/map等自定义算子中手动发送了水印、或者拆分了算子链导致水印传递中断,窗口算子实际拿到的水印会和你打印的debug水印不一致,可以在keyBy之后、window之前再加一层水印打印,确认水印传递链路正常。
内容的提问来源于stack exchange,提问作者tuk
相关产品推荐