You need to enable JavaScript to run this app. Flink 1.12.2流处理作业全部事件被判定为迟到丢弃问题排查求助
优惠活动
大模型
产品
解决方案
定价
更多

Flink 1.12.2流处理作业全部事件被判定为迟到丢弃问题排查求助

Flink事件时间窗口所有事件都被判定为迟到进入侧输出如何排查?

我的Flink流处理管道代码如下:

FlinkKafkaConsumerBase kafkaConsumer = new FlinkKafkaConsumer<>(topic, new DeserializationSchema(),props);

kafkaSource = env.addSource(kafkaConsumer).filter(<>);
WatermarkStrategy<GenericMetricV2> watermarkStrategy = WatermarkStrategy
                .<GenericMetricV2>forBoundedOutOfOrderness(Duration.ofSeconds(900))
                .withTimestampAssigner((metric, timestamp) -> {
                    logger.info("ETS: mts: {}, ts: {}", metric.metricPoint.timeInstant, timestamp);
                    return metric.metricPoint.timeInstant;
                });

metricStream = kafkasource
                        .process(<>).assignTimestampsAndWatermarks(watermarkStrategy)
                        .transform("debugFilter", TypeInformation.of(<>), new StreamWatermarkDebugFilter<>("Op"))
                        .filter(<>).map(<>).flatMap(<>).keyBy(<>)
                        .window(TumblingEventTimeWindows.of(Time.seconds(300)))
                        .allowedLateneess(Time.seconds(900))
                        .sideOutputLateData(lateOutputTag)
                        .aggregate(AggregateFunction, ProcessWindowFunction)
                        .addSink()

当前作业并行度为1,采用默认200ms的setAutowatermarkInterval配置,由于Flink 1.12版本默认采用事件时间语义,因此我未额外设置setStreamTimeCharacteristic参数。

通过StreamWatermarkDebugFilter的输出我可以看到水印在正常推进,但是所有事件都被标记为迟到,被收集到lateOutputTag中,相关日志如下:

2021-05-18 17:14:19,745 INFO                  - ETS: mts: 1621310100000, ts: 1621310582271
2021-05-18 17:14:19,745 INFO                  - ETS: mts: 1621310100000, ts: 1621310582271
2021-05-18 17:14:19,842 INFO  StreamWatermarkDebugFilter         - Op, Watermark: 1621309499999
2021-05-18 17:14:19,944 INFO                  - ETS: mts: 1621309800000, ts: 1621310582275
2021-05-18 17:14:19,944 INFO                  - ETS: mts: 1621309800000, ts: 1621310582275
...
2021-05-18 17:14:20,107 INFO                  - ETS: mts: 1621310380000, ts: 1621310582278
2021-05-18 17:14:20,107 INFO                  - ETS: mts: 1621310380000, ts: 1621310582278
2021-05-18 17:14:20,137 INFO  StreamWatermarkDebugFilter         - Op, Watermark: 1621309779999
2021-05-18 17:14:20,203 INFO                  - ETS: mts: 1621309800000, ts: 1621310582279
...
2021-05-18 17:17:47,839 INFO                  - ETS: mts: 1621310100000, ts: 1621310681159
2021-05-18 17:17:47,848 INFO  StreamWatermarkDebugFilter         - Op, Watermark: 1621310099999
2021-05-18 17:17:47,958 INFO                  - ETS: mts: 1621309800000, ts: 1621310681237
2021-05-18 17:17:47,958 INFO                  - ETS: mts: 1621309800000, ts: 1621310681237
...
2021-05-18 17:22:24,207 INFO                  - ETS: mts: 1621310100000, ts: 1621310703622
2021-05-18 17:22:24,229 INFO  StreamWatermarkDebugFilter         - Op, Watermark: 1621310399999
2021-05-18 17:22:24,315 INFO                  - ETS: mts: 1621309800000, ts: 1621310705177
2021-05-18 17:22:24,315 INFO                  - ETS: mts: 1621309800000, ts: 1621310705177

我已经确认不是数据源空闲导致的问题,请问该如何进一步排查定位该问题的根因?

排查方案
  • 优先检查配置拼写错误
    你代码中的allowedLateneess拼写错误,Flink官方正确的方法名是allowedLateness,拼写错误会导致允许迟到的配置不生效,默认允许迟到时间为0,只要水印超过窗口结束时间,后续到达的事件都会直接被判定为迟到进入侧输出,这是最高概率的根因。
  • 验证流引用是否正确
    你代码中定义的源变量是kafkaSource(大写S),但后续构造metricStream时用的是kafkasource(小写s),如果实际代码中这是两个不同的流对象,那么你配置的水印策略根本没有应用到窗口所在的流上,会导致窗口算子拿到的水印不符合预期。
  • 校验窗口关闭阈值匹配逻辑
    你使用的是5分钟滚动事件时间窗口,允许迟到15分钟,单个窗口的关闭阈值为窗口结束时间 + 15分钟,你可以在窗口算子前新增日志,打印每个事件的时间戳、所属窗口的起止时间、窗口关闭阈值,同时打印当前算子收到的水印,只要水印超过窗口关闭阈值,事件就会被判定为迟到,对比数值即可确认逻辑是否符合预期。
  • 排查水印传递链路是否正常
    你当前的水印debug日志是在水位线生成后直接打印的,如果后续的process/filter/map等自定义算子中手动发送了水印、或者拆分了算子链导致水印传递中断,窗口算子实际拿到的水印会和你打印的debug水印不一致,可以在keyBy之后、window之前再加一层水印打印,确认水印传递链路正常。

内容的提问来源于stack exchange,提问作者tuk