Let’s walk through the most likely issues causing your problem, and how to fix them step by step:
1. First: Validate the mosquitto_pub Command & Message Format
Your current setup has a couple of critical details that might be breaking things:
Unstructured message payload: You’re sending
'"103.3223","3.2322"'— this is just two string values without attribute names. The Vorto Semantic Normalizer relies on structured JSON with key-value pairs that match your Vorto model’s property names. For example, if your model defineslatitudeandlongitudeproperties, your payload should look like:{"latitude": 103.3223, "longitude": 3.2322}Without these clear keys, the normalizer has no way to map your raw values to semantic attributes.
Missing verbose debug output: Add the
-vflag to yourmosquitto_pubcommand to get detailed logs. This will tell you if the connection to Bosch IoT Hub succeeded, if the message was sent, or if there’s an authentication/network error. Here’s the updated command:mosquitto_pub -h mqtt.bosch-iot-hub.com -p 8883 -u 4712@t65a6a75c6b4f429981ba16d1b3d5f414 -P secret -t telemetry/t65a6a75c6b4f429981ba16d1b3d5f414/4712 -m '{"latitude":103.3223,"longitude":3.2322}' --cafile iothub.crt -vLook for lines like
Client ... sending CONNECTandClient ... sending PUBLISH— if these don’t appear, you’ve got a connection or authentication issue.CA certificate path: Double-check that
iothub.crtis in your current working directory, or use an absolute path (e.g.,/home/yourname/certs/iothub.crt) to avoid path-related errors.
2. Verify Bosch IoT Hub Authentication & Topic
- Credentials check: Ensure your username (
4712@t65a6a75c6b4f429981ba16d1b3d5f414) and password (secret) match exactly what’s configured for your device in the Bosch IoT Hub console. Typos or extra spaces here will silently fail authentication. - Topic correctness: Your telemetry topic
telemetry/t65a6a75c6b4f429981ba16d1b3d5f414/4712follows the correct Bosch IoT Hub format (telemetry/<tenant-id>/<device-id>), but confirm the tenant ID and device ID are spelled correctly (they’re case-sensitive!).
3. Fix Vorto Semantic Normalizer Mapping
If the message reaches the hub but isn’t being mapped, these are the key checks:
- Model binding: Make sure your device is linked to the correct Vorto information model in the Bosch IoT Hub console. Without this association, the normalizer doesn’t know which semantic schema to apply.
- Payload type matching: Ensure the data types in your JSON payload match the Vorto model’s definitions. For example, if your model expects a
floatfor latitude, send a numeric value (not a string like"103.3223"). - Middleware configuration: Confirm the Vorto Semantic Normalizer is configured to listen to your device’s telemetry topic. If it’s only monitoring a different topic, your messages will be ignored entirely.
Quick Test Steps to Isolate the Problem
- Run the verbose
mosquitto_pubcommand above. If you see no errors and the publish is confirmed, the issue is likely with the Vorto setup, not message delivery. - Check the Bosch IoT Hub device logs (in the console under your device’s "Logs" tab) — look for entries related to authentication failures, rejected messages, or model mismatches.
- Send a simple, fully structured JSON payload that exactly matches your Vorto model’s properties, then check if the normalizer processes it.