Python多线程传值:如何在RFID、温感、PIR传感器所属线程间传递数据
安防系统线程联动实现方案
你可以通过线程安全的状态事件、共享变量加锁的方式实现需求,不需要复杂的线程通信机制,修改步骤如下:
1. 初始化线程安全的控制变量
在类中新增线程安全的控制对象与共享变量,避免多线程读写冲突,同时把数据库配置移到类属性,替换冗余的全局变量:
import threading # 保留原有其他导入项 class Security: # 数据库配置移到类属性 dbHost = 'localhost' dbUser = 'root' dbPass = 'iTdev#2020' dbNameEmp = 'empinfo' dbNameSecure = 'secureinfo' # PIR传感器默认禁用时长,单位秒,可根据需求调整 PIR_DISABLE_SECONDS = 10 def __init__(self): self.msg = "" # PIR禁用控制事件:事件处于set状态时PIR停止工作 self.pir_disable_event = threading.Event() # 最新温度共享变量 + 读写锁,保证多线程读写的原子性 self.latest_temperature = None self.temp_lock = threading.Lock() # PIR禁用倒计时计时器 self.pir_disable_timer = None
2. 封装PIR禁用通用逻辑
把PIR临时禁用、到期自动恢复的逻辑封装为公用方法,避免RFID和温度模块重复编写代码:
def disable_pir_temp(self): """临时禁用PIR传感器,到达指定时长后自动恢复""" # 取消之前未完成的倒计时,避免多次触发冲突 if self.pir_disable_timer and self.pir_disable_timer.is_alive(): self.pir_disable_timer.cancel() # 激活PIR禁用状态 self.pir_disable_event.set() # 启动倒计时,到期后自动解除禁用 self.pir_disable_timer = threading.Timer(self.PIR_DISABLE_SECONDS, self.pir_disable_event.clear) self.pir_disable_timer.start()
3. 修改PirSensor方法响应禁用状态
调整PIR传感器的循环逻辑,检测到禁用事件激活时跳过运动检测:
def PirSensor(self): while True: # PIR处于禁用状态时休眠跳过检测 if self.pir_disable_event.is_set(): time.sleep(0.2) continue # 原有检测、报警逻辑完全保留 led_blue.on() time.sleep(0.1) current_state = GPIO.input(pir_sensor) if current_state == 1: print("GPIO pin %s is %s" % (pir_sensor, current_state)) GPIO.output(relay_alarm,True) led_blue.off() led_red.blink(0.1, 0.2) time.sleep(5) GPIO.output(relay_alarm,False) led_red.off() led_yellow.blink(0.5, 0.5) time.sleep(5) led_yellow.off()
4. 修改Temperature方法同步温度+触发PIR禁用
测温成功后更新共享温度变量,同时触发PIR禁用:
def Temperature(self): while True: # 原有测距逻辑完全保留 GPIO.output(TRIG, False) time.sleep(0.5) GPIO.output(TRIG, True) time.sleep(0.01) GPIO.output(TRIG, False) while GPIO.input(ECHO) == 0 : pulse_start = time.time() while GPIO.input(ECHO) == 1 : pulse_end = time.time() pulse_duration = pulse_end - pulse_start distance = pulse_duration * 11150 distance = round(distance,2) if distance > 0 and distance < 3 : # 原有测温、屏幕显示逻辑完全保留 buzzer.on() time.sleep(0.1) buzzer.off() print ("Distance: %scm" % (distance)) temp_val = sensor.get_object_1() print ("Temperature: %.1fc" % temp_val) msgTemp = ("%.1f" % temp_val) w, h = textsize(msgTemp, font=proportional(CP437_FONT)) if w <= device.width: x = round((device.width - w) / 2) with canvas(device) as draw: text(draw, (x, 0), msgTemp, fill="white", font=proportional(CP437_FONT)) else: show_message(device, msgTemp, fill="white", font=proportional(CP437_FONT),scroll_delay=0.04) time.sleep(1) device.clear() # 新增逻辑:加锁更新共享温度+禁用PIR with self.temp_lock: self.latest_temperature = temp_val self.disable_pir_temp()
5. 修改rfid_callback方法读取温度+触发PIR禁用
RFID记录保存成功后,读取最新温度写入数据库,同时触发PIR禁用:
def rfid_callback(self, state, dev): rfid_presented = "" keys = "X^1234567890XXXXqwertzuiopXXXXasdfghjklXXXXXyxcvbnmXXXXXXXXXXXXXXXXXXXXXXX" while True: r,w,x = select([dev], [], []) for event in dev.read(): if event.type==1 and event.value==1: if event.code==28: rfid_presented = rfid_presented.replace("X", "") travel = state.replace("Thread-", "") # 原有拼接SQL的写法存在注入风险,改为参数化查询 dbConnEmp = mysql.connect(host=self.dbHost, user=self.dbUser, passwd=self.dbPass, db=self.dbNameEmp) curEmp = dbConnEmp.cursor() curEmp.execute("Select RFidEmp FROM RFidMaster WHERE (RFidStatus = 1) AND RFidNumber = %s", (rfid_presented,)) resultRFid = curEmp.fetchone() if curEmp.rowcount != 1: with canvas(device) as draw: text(draw, (0, 0), "None", fill="white", font=proportional(CP437_FONT)) time.sleep(0.5) device.clear() else: dbConnSecure = mysql.connect(host=self.dbHost, user=self.dbUser, passwd=self.dbPass, db=self.dbNameSecure) curSecure = dbConnSecure.cursor() curSecure.execute("SELECT EntraId,DATE_FORMAT(CreateDate, '%Y%m%d') AS CreateDate FROM entranlog ORDER BY EntraId DESC, CreateDate DESC LIMIT 1") resultKey = curSecure.fetchone() KeyDate = time.strftime("%Y%m%d") if curSecure.rowcount != 1: KeyId = KeyDate+"0001" else: if resultKey[1] == KeyDate: KeyId = str(int(resultKey[0]) + 1) else: KeyId = KeyDate+"0001" create_date = time.strftime('%Y-%m-%d %H:%M:%S') # 新增:加锁读取最新温度 with self.temp_lock: record_temp = self.latest_temperature # 修改插入语句,增加温度字段(需提前在数据库entranlog表新增Temperature浮点型字段) insertSecure = "INSERT INTO entranlog (EntraId,EntraAction,EntraStatus,CreateBy,CreateDate,Temperature) VALUES (%s,%s,%s,%s,%s,%s)" valSecure = (KeyId,travel,1,resultRFid[0],create_date,record_temp) curSecure.execute(insertSecure, valSecure) dbConnSecure.commit() with canvas(device) as draw: text(draw, (0, 0), "Hello", fill="white", font=proportional(CP437_FONT)) print(curSecure.rowcount, "record inserted.") time.sleep(0.8) device.clear() # 新增:RFID数据保存成功后禁用PIR self.disable_pir_temp() rfid_presented = "" else: rfid_presented += keys[ event.code ]
额外注意
- 提前在数据库
entranlog表新增Temperature浮点类型字段,用于存储温度记录 - 所有数据库操作建议统一使用参数化查询,避免SQL注入风险
- 可根据实际使用场景调整
PIR_DISABLE_SECONDS的禁用时长
内容的提问来源于stack exchange,提问作者Mr. Search
相关产品推荐
相关产品推荐