vsim-3015告警排查:FIFO模块wrdata/rddata端口位宽与连接位宽不匹配
SystemVerilog FIFO仿真vsim-3015告警问题排查
告警信息
Warning: (vsim-3015) [PCDPC] - Port size (8) does not match connection size (7) for port 'wrdata'. The port definition is at: design.sv(2).
Time: 0 ns Iteration: 0 Instance: /tb/DUT File: testbench.sv Line: 15Warning: (vsim-3015) [PCDPC] - Port size (8) does not match connection size (7) for port 'rddata'. The port definition is at: design.sv(2).
Time: 0 ns Iteration: 0 Instance: /tb/DUT File: testbench.sv Line: 15
触发原因
问题出在Testbench的位宽声明语法错误:
- FIFO设计中
wrdata、rddata的位宽声明为[WIDTH-1:0],当WIDTH=8时是8位(位宽范围7到0) - Testbench中错误地将
wrdata、rddata声明为[WIDTH-1],缺失了低位边界:0,仿真器将该声明解析为[WIDTH-2:0](共7位),导致和DUT端口位宽不匹配,触发告警。
修复方案
修改Testbench中wrdata和rddata的位宽声明,补全低位边界:0即可。
错误代码行(testbench.sv)
reg [WIDTH-1] wrdata; wire [WIDTH-1] rddata;
修正后代码
reg [WIDTH-1:0] wrdata; wire [WIDTH-1:0] rddata;
仿真告警截图

内容的提问来源于stack exchange,提问作者Adharsh