Android日志高频打印qmi_cci_get_ref内容的含义及是否需修复
结论
这两条高频循环日志与Jetpack Compose应用代码无关,不属于应用层需要修复的问题,是设备底层系统固件遗留的调试打印,不会影响应用正常运行。
日志片段参考
2022-06-13 18:22:46.038 1097-1184/? E/QMI_FW: qmi_cci_get_ref: ref count increased 2 2022-06-13 18:22:46.038 1097-1184/? I/ASH: @ 1673484.579: tcs3701: stop power rail pending_off timer 2022-06-13 18:22:46.125 1097-1184/? E/QMI_FW: qmi_cci_get_ref: ref count increased 2 2022-06-13 18:22:46.125 1097-1184/? I/ASH: @ 1673484.666: tcs3701: stop power rail pending_off timer 2022-06-13 18:22:46.212 1097-1184/? E/QMI_FW: qmi_cci_get_ref: ref count increased 2 2022-06-13 18:22:46.212 1097-1184/? I/ASH: @ 1673484.753: tcs3701: stop power rail pending_off timer 2022-06-13 18:22:46.300 1097-1184/? E/QMI_FW: qmi_cci_get_ref: ref count increased 2 ...
两条日志的具体含义
E/QMI_FW: qmi_cci_get_ref: ref count increased 2
这是高通平台调制解调器接口(QMI)框架的调试日志。qmi_cci_get_ref是QMI客户端接口层维护引用计数的内部接口,这条日志仅用于记录引用计数自增的操作,虽然被标记为Error级别,但实际不属于错误,是固件开发阶段遗留的调试打印。日志对应的PID 1097是系统底层硬件服务进程,和应用进程无关。I/ASH: @ xxx: tcs3701: stop power rail pending_off timer
这是环境光传感器(tcs3701为AMS厂商的环境光传感器型号)驱动层的状态日志,含义是传感器驱动停止了电源轨的待关断定时器,是传感器处于持续工作状态时反复触发的常规状态打印,同样属于驱动层未关闭的冗余调试日志。
高频输出原因
该现象是设备厂商或第三方ROM编译系统固件时,未关闭底层驱动、高通框架的调试日志开关导致:系统底层的传感器服务、调制解调器服务按固定周期(从时间戳判断约87ms一次,对应11Hz轮询频率)执行常规操作,每执行一次就打印一条调试日志,最终形成无限循环刷屏的效果。
处理建议
- 应用开发阶段无需针对该现象修改任何业务代码,这类日志不会造成应用功能异常或额外性能损耗,仅会占用日志缓冲区空间
- 若日志刷屏影响调试,可在Android Studio Logcat中配置过滤规则,屏蔽
QMI_FW、ASH两个tag的日志 - 仅当你从事系统ROM开发时,才需要到对应驱动、QMI框架层关闭冗余调试打印的开关。
内容的提问来源于stack exchange,提问作者BenjyTec
相关产品推荐
相关产品推荐