VB.NET中PLC变量无法保留设置及初始化异常问题求助
问题描述
每次扫描后plc变量都会恢复默认值,请问如何保留上次设置的值?
我尝试用GetSetting和SaveSetting函数来实现,示例代码如下:
Private Sub TxtBox_IPAdress_TextChanged(sender As Object, e As EventArgs) SaveSetting(My.Application.Info.AssemblyName, "DadosGerais", "PLC1_IP", TxtBox_IPAdress.Text) End Sub
完整代码:
Option Explicit On Imports S7.Net Module GlobalVar ' Public PLC As Plc ' Public Errorlist As exceptionCode Public Valor_do_loop_pre_defenido As Integer = 100 'valor médio pretendido para o tempo de ciclo/loop da aplicação Public hhextracao As String '= "hh" Public mmextracao As String '= "mm" Public ssextracao As String '= "ss" Public thisDay As String '= Date.Now.ToString("dd") Public thisMonth As String '= Date.Now.ToString("MM") Public thisYear As String '= Date.Now.ToString("yyyy") Public thisHour As String '= Date.Now.ToString("HH") Public thisMinute As String '= Date.Now.ToString("mm") Public thisSec As String '= Date.Now.ToString("ss") Public PLC1_IP As String Public PLC1_Rack As Integer Public PLC1_Slot As Integer Public Select_PLC1_Type As Integer Public PLC1_Type As CpuType Public PLC1 As New Plc(PLC1_Type, PLC1_IP, PLC1_Rack, PLC1_Slot) Public test1 As Boolean Public test1_in As Boolean Public test1_out As Boolean Public Sub Settings_Read() PLC1_IP = GetSetting(My.Application.Info.AssemblyName, "DadosGerais", "PLC1_IP", "192.168.0.10") PLC1_Rack = GetSetting(My.Application.Info.AssemblyName, "DadosGerais", "PLC1_Rack", "0") PLC1_Slot = GetSetting(My.Application.Info.AssemblyName, "DadosGerais", "PLC1_Slot", "1") Select_PLC1_Type = GetSetting(My.Application.Info.AssemblyName, "DadosGerais", "Select_PLC1_Type", "3") Select Case Select_PLC1_Type Case 0 PLC1_Type = CpuType.S7200 Case 1 PLC1_Type = CpuType.S7300 Case 2 PLC1_Type = CpuType.S7400 Case 3 PLC1_Type = CpuType.S71200 Case 4 PLC1_Type = CpuType.S71500 Case 5 PLC1_Type = CpuType.S7200Smart Case 6 PLC1_Type = CpuType.Logo0BA8 Case Else 'default PLC1_Type = CpuType.S7300 ' ComboBox_CPUType.SelectedIndex = ComboBox_CPUType_SelectedIndex End Select ' Dim PLC As New Plc(PLC1_Type, PLC1_IP, PLC1_Rack, PLC1_Slot) ' PLC1 = PLC End Sub End Module
遇到的错误
抛出System.TypeInitializationException异常:the type initializer for 'siemensConnext.globalvar' threw an exception
内部异常:ArgumentException: IP address must be valid. Parameter: ip
解决方案
1. 修复初始化顺序问题
核心错误是全局变量初始化顺序错误:PLC1作为全局变量,会在Settings_Read()执行前就被实例化,此时PLC1_IP是空字符串,直接导致IP地址无效的参数异常。
修改步骤:
- 仅声明
PLC1变量,不立即实例化 - 在
Settings_Read()读取完所有配置后,再创建Plc实例并赋值给PLC1
修改后的代码:
Option Explicit On Imports S7.Net Module GlobalVar Public Valor_do_loop_pre_defenido As Integer = 100 Public hhextracao As String Public mmextracao As String Public ssextracao As String Public thisDay As String Public thisMonth As String Public thisYear As String Public thisHour As String Public thisMinute As String Public thisSec As String Public PLC1_IP As String Public PLC1_Rack As Integer Public PLC1_Slot As Integer Public Select_PLC1_Type As Integer Public PLC1_Type As CpuType ' 仅声明变量,不立即实例化 Public PLC1 As Plc Public test1 As Boolean Public test1_in As Boolean Public test1_out As Boolean Public Sub Settings_Read() ' 读取配置,注意转换为对应数据类型 PLC1_IP = GetSetting(My.Application.Info.AssemblyName, "DadosGerais", "PLC1_IP", "192.168.0.10") PLC1_Rack = CInt(GetSetting(My.Application.Info.AssemblyName, "DadosGerais", "PLC1_Rack", "0")) PLC1_Slot = CInt(GetSetting(My.Application.Info.AssemblyName, "DadosGerais", "PLC1_Slot", "1")) Select_PLC1_Type = CInt(GetSetting(My.Application.Info.AssemblyName, "DadosGerais", "Select_PLC1_Type", "3")) ' 确定PLC类型 Select Case Select_PLC1_Type Case 0 PLC1_Type = CpuType.S7200 Case 1 PLC1_Type = CpuType.S7300 Case 2 PLC1_Type = CpuType.S7400 Case 3 PLC1_Type = CpuType.S71200 Case 4 PLC1_Type = CpuType.S71500 Case 5 PLC1_Type = CpuType.S7200Smart Case 6 PLC1_Type = CpuType.Logo0BA8 Case Else PLC1_Type = CpuType.S7300 End Select ' 读取配置后再实例化PLC PLC1 = New Plc(PLC1_Type, PLC1_IP, PLC1_Rack, PLC1_Slot) End Sub End Module
2. 确保配置读取时机正确
在程序启动的最早阶段(比如主窗体的Form_Load事件)调用Settings_Read(),确保所有配置加载完成后再使用PLC1变量:
Private Sub MainForm_Load(sender As Object, e As EventArgs) Handles MyBase.Load GlobalVar.Settings_Read() ' 后续操作PLC1的代码放在这里 End Sub
3. 完善配置保存逻辑
确保所有需要保留的参数(机架号、槽号、PLC类型等)都在对应控件值变化时调用SaveSetting,比如PLC类型选择框的事件:
Private Sub ComboBox_CPUType_SelectedIndexChanged(sender As Object, e As EventArgs) SaveSetting(My.Application.Info.AssemblyName, "DadosGerais", "Select_PLC1_Type", ComboBox_CPUType.SelectedIndex.ToString()) End Sub
这样修改后,程序启动时会先读取上次保存的配置,再初始化PLC实例,既解决了IP无效的异常,也能完整保留用户上次设置的所有参数。