心脏病预测Scikit-learn Pipeline转ONNX后加载推理失败求助
问题解决:ONNX加载Scikit-learn Pipeline模型失败
问题描述
搭建了用于心脏病预测的Scikit-learn Pipeline,已成功转换为ONNX格式,但加载模型推理时失败,报错如下:
Fail: [ONNXRuntimeError] : 1 : FAIL : Load model from ./pipeline_xgboost.onnx failed:Node (LabelEncoder2) Op (LabelEncoder) [ShapeInferenceError] Input type is not int64 tensor but keys_int64s is set.
当前定义的输入类型:
input_types = [ ('age', FloatTensorType(shape=[None, 1])), #could not parse age as int ('sex', Int64TensorType(shape=[None, 1])), ('cp', Int64TensorType(shape=[None, 1])), ('trestbps', Int64TensorType(shape=[None, 1])), ('chol', Int64TensorType(shape=[None, 1])), ('fbs', Int64TensorType(shape=[None, 1])), ('restecg', Int64TensorType(shape=[None, 1])), ('thalach', Int64TensorType(shape=[None, 1])), ('exang', Int64TensorType(shape=[None, 1])), ('oldpeak', FloatTensorType(shape=[None, 1])), ('slope', Int64TensorType(shape=[None, 1])), ('ca', Int64TensorType(shape=[None, 1])), ('thal', StringTensorType(shape=[None, 1]))]
原因分析
报错核心是:LabelEncoder2节点配置了keys_int64s(即用整数作为编码映射的键),但该节点对应的输入张量类型不是int64,类型不匹配导致模型加载失败。
解决步骤
定位
LabelEncoder2对应的特征
查看你的Scikit-learn Pipeline结构,找到标记为LabelEncoder2的预处理步骤,确认它对应的是哪个输入特征(比如ca、slope或其他特征)。修正输入类型与LabelEncoder的匹配性
- 若该LabelEncoder是用来编码整数类特征的(训练时输入为整数),则对应特征的输入类型必须设为
Int64TensorType,检查当前输入类型定义中该特征的类型是否正确,错误则修正。 - 若该LabelEncoder实际处理字符串特征,需确认转换ONNX时是否错误配置了
keys_int64s参数,此时应将对应特征的输入类型设为StringTensorType,重新转换模型时指定正确的编码键类型。
- 若该LabelEncoder是用来编码整数类特征的(训练时输入为整数),则对应特征的输入类型必须设为
重新转换并验证模型
修正输入类型定义后,使用skl2onnx重新将Pipeline转换为ONNX格式,再尝试加载模型推理,确认问题是否解决。
内容的提问来源于stack exchange,提问作者TheHumanSpider
相关产品推荐
相关产品推荐