Node-OPCUA对接Codesys PLC时报警确认报“Acknowledge Method Not Found”错误
Node-OPCUA调用报警确认方法报错:cannot find Acknowledge Method(对接Codesys PLC)
环境与目标
- OPC UA客户端:Node-OPCUA v2.115.0,Node.js v20.10.0
- 操作系统:Windows 11 Pro(版本10.0.22631 Build 22631)
- 设备:华硕灵耀(ASUS ZenBook)笔记本
- 对接目标:CODESYS Control Win V3 x64(版本3.5.19.3)的OPC UA服务器,实现报警确认功能
当前问题
已成功连接本地Codesys PLC,可正常读写数值、查看报警状态,但调用acknowledgeCondition或confirmCondition函数确认报警时,触发错误:Error: cannot find Acknowledge Method。传入的ConditionId和EventId均来自EventMonitor.on()的返回值,而UAExpert可正常完成报警确认操作,推测问题出在Node-OPCUA客户端实现上。
预期行为
调用报警确认方法后,报警状态应同步更新到Codesys PLC中,标记为已确认。
相关代码
import express from "express"; import { createServer } from 'node:http'; import { AttributeIds, OPCUAClient, TimestampsToReturn, constructEventFilter, ObjectIds } from "node-opcua"; const app = express(); const server = createServer(app); const URL = "opc.tcp://ADRIAN-ASUS:4840"; (async () => { try { const client = OPCUAClient.create(); client.on("backoff", (retry, delay) => { console.log("Retying to connect to ", URL, " attempt ", retry); }); console.log("connecting to ", URL); await client.connect(URL); console.log("connected to ", URL); const session = await client.createSession(); console.log("session initialized"); const subscripcion = await session.createSubscription2({ requestedPublishingInterval: 50, requestedMaxKeepAliveCount: 20, publishingEnabled: true, }); const fields = [ "EventId", "AckedState", "AckedState.Id", "ConfirmedState", "ConfirmedState.Id", "ConditionId", ]; const eventFilter = constructEventFilter(fields); const itemToMonitor = { nodeId: ObjectIds.Server, attributeId: AttributeIds.EventNotifier, }; const parameters = { filter: eventFilter, discardOldest: true, queueSize: 100, }; const EventMonitor = await subscripcion.monitor( itemToMonitor, parameters, TimestampsToReturn.Both ) const alarmData = {}; EventMonitor.on("changed", (events) => { for (let i = 0; i < events.length; i++) { alarmData[fields[i]] = events[i].value; } }); setTimeout(async () => { try { const comment = 'Comment random'; console.log({conditionId: alarmData.ConditionId, eventId: alarmData.EventId}); session.acknowledgeCondition(alarmData.ConditionId, alarmData.EventId, comment, (err) => { console.log({ err }); }); } catch (error) { console.log(error); } }, 5000); let running = true; process.on("SIGINT", async () => { if (!running) return; console.log("shutting down client"); running = false; await subscripcion.terminate(); await session.close(); await client.disconnect(); console.log("Done"); process.exit(0); }); } catch (error) { console.log("ERROR: ", error.message); console.log(error); } server.listen(4000, () => { console.log('server running at http://localhost:4000'); }); })();
错误与日志
- 报警确认触发的错误:
Error: cannot find Acknowledge Method conditionId和eventId控制台输出:{ conditionId: { dataType: 'NodeId', value: 'ns=4;s=|var|CODESYS Control Win V3 x64.Application.GVL.AlarmTest' }, eventId: { dataType: 'ByteString', value: <Buffer 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00> } }- 调试发现
translateBrowsePath回调返回状态码:statusCode: BadNodeIdUnknown (0x80340000) { _description: 'The node id refers to a node that does not exist in the server address space.', _name: 'BadNodeIdUnknown', _value: 2150891520, }
补充信息
- Node-OPCUA通过npm安装
- UAExpert可正常查看并完成报警确认,排除服务器端问题
- 尝试更换多个Node.js版本,问题未解决
内容的提问来源于stack exchange,提问作者Adrian Acurero
相关产品推荐