mpi4py+Slurm进程启动报错:插槽不足及UCX错误解决方案咨询
问题描述
我正在使用mpi4py,通过以下Slurm作业脚本提交任务:
#!/bin/bash #SBATCH -N 2 #SBATCH --ntasks-per-core=2 module load --auto python/3.9.15-gcc-12.2.0-3sr5utz module load --auto py-pandas/1.5.1-gcc-12.2.0-356d2ew module load --auto py-scipy/1.8.1-gcc-12.2.0-7uvxgvy module load --auto py-joblib/1.2.0-gcc-12.2.0-ecughwi module load --auto py-mpi4py/3.1.3-gcc-12.2.0-xvabib2 mpirun --use-hwthread-cpus --np 1 python3 -u ./master.py 510
我希望启动1个主进程并派生510个子进程。每个节点拥有128个物理核心,每个核心支持2个线程,申请2个节点后我认为应该有足够的插槽来派生510个子进程,但却收到错误:
There are not enough slots available in the system to satisfy the 510 slots that were requested by the application
请问在不使用oversubscribe参数的情况下,如何充分利用所有逻辑核心?
补充说明:若使用--oversubscribe参数,则会出现如下UCX错误:
[1706365618.473220] [n3511-017:303072:0] wireup.c:400 UCX ERROR ep 0x14b4ac04a180: no remote ep address for lane[2]->remote_lane[2] [1706365618.473256] [n3511-017:303072:0] wireup.c:400 UCX ERROR ep 0x14b4ac04a080: no remote ep address for lane[2]->remote_lane[2] [1706365618.473469] [n3511-017:303072:0] wireup.c:400 UCX ERROR ep 0x14b4ac04a100: no remote ep address for lane[2]->remote_lane[2] [1706365618.473480] [n3511-017:303072:0] wireup.c:400 UCX ERROR ep 0x14b4ac04a240: no remote ep address for lane[2]->remote_lane[2] [1706365618.480337] [n3511-017:303072:0] wireup.c:400 UCX ERROR ep 0x14b4ac04a480: no remote ep address for lane[2]->remote_lane[2] [1706365618.480349] [n3511-017:303072:0] wireup.c:400 UCX ERROR ep 0x14b4ac04a040: no remote ep address for lane[2]->remote_lane[2] [1706365618.480359] [n3511-017:303072:0] wireup.c:400 UCX ERROR ep 0x14b4ac04a540: no remote ep address for lane[2]->remote_lane[2] [1706365618.480605] [n3511-029:76140:a] wireup.c:1071 UCX ERROR old: am_lane 0 wireup_msg_lane <none> cm_lane <none> keepalive_lane <none> reachable_mds 0x12 [1706365618.480649] [n3511-029:76140:a] wireup.c:1094 UCX ERROR old: lane[0]: 6:dc_mlx5/mlx5_0:1.0 md[4] -> md[4]/ib/sysdev[255] rma_bw#0 am am_bw#0 [1706365618.480659] [n3511-029:76140:a] wireup.c:1071 UCX ERROR new: am_lane 0 wireup_msg_lane 0 cm_lane <none> keepalive_lane <none> reachable_mds 0x12 [1706365618.480668] [n3511-029:76140:a] wireup.c:1094 UCX ERROR new: lane[0]: 10:ud_mlx5/mlx5_0:1.0 md[4] -> md[4]/ib/sysdev[255] am am_bw#0 wireup [n3511-029:76140:a:79452] wireup.c:1384 Fatal: endpoint reconfiguration not supported yet [1706365618.481141] [n3511-029:76141:a] wireup.c:1071 UCX ERROR old: am_lane 0 wireup_msg_lane <none> cm_lane <none> keepalive_lane <none> reachable_mds 0x12 [1706365618.481172] [n3511-029:76141:a] wireup.c:1094 UCX ERROR old: lane[0]: 6:dc_mlx5/mlx5_0:1.0 md[4] -> md[4]/ib/sysdev[255] rma_bw#0 am am_bw#0 [1706365618.481182] [n3511-029:76141:a] wireup.c:1071 UCX ERROR new: am_lane 0 wireup_msg_lane 0 cm_lane <none> keepalive_lane <none> reachable_mds 0x12 [1706365618.481193] [n3511-029:76141:a] wireup.c:1094 UCX ERROR new: lane[0]: 10:ud_mlx5/mlx5_0:1.0 md[4] -> md[4]/ib/sysdev[255] am am_bw#0 wireup [n3511-029:76141:a:78916] wireup.c:1384 Fatal: endpoint reconfiguration not supported yet ==== backtrace (tid: 79452) ==== 0 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucs.so.0(ucs_handle_error+0x294) [0x14c65c229e94] 1 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucs.so.0(ucs_fatal_error_message+0xca) [0x14c65c22700a] 2 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucs.so.0(+0x2c0e1) [0x14c65c2270e1] 3 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucp.so.0(ucp_wireup_init_lanes+0xf77) [0x14c65c93d047] 4 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucp.so.0(+0x90359) [0x14c65c93d359] 5 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucp.so.0(+0x90be1) [0x14c65c93dbe1] 6 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/ucx/libuct_ib.so.0(uct_ud_ep_process_rx+0x1fa) [0x14c6581ec29a] 7 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/ucx/libuct_ib.so.0(+0x631cb) [0x14c6581f51cb] 8 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/ucx/libuct_ib.so.0(+0x5503b) [0x14c6581e703b] 9 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucs.so.0(+0x181dc) [0x14c65c2131dc] 10 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucs.so.0(ucs_async_dispatch_handlers+0x4c) [0x14c65c213e8c] 11 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucs.so.0(+0x1b9a6) [0x14c65c2169a6] 12 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucs.so.0(ucs_event_set_wait+0xa9) [0x14c65c2333e9] 13 /gpfs/opt/sw/zen/spack-0.19.0/opt/spack/linux-almalinux8-zen3/gcc-12.2.0/ucx-1.13.1-p4m2lkzrqib6jwxuqkqdocfmyka7bvoh/lib/libucs.so.0(+0x1bff7) [0x14c65c216ff7] 14 /lib64/libpthread.so.0(+0x81ca) [0x14c6715351ca] 15 /lib64/libc.so.6(clone+0x43) [0x14c670a17e73]
解决方案
2个节点×128物理核心×2线程=512个逻辑核心,足够容纳1+510=511个进程,核心问题是当前Slurm配置和mpirun调用未正确声明并使用所有插槽,以下是具体调整方案:
1. 修正Slurm作业参数
--ntasks-per-core=2仅允许每个物理核心跑2个任务,但需要显式声明总任务数或让Slurm自动分配全部插槽。修改Slurm头部:
#!/bin/bash #SBATCH -N 2 #SBATCH --ntasks-per-core=2 #SBATCH --ntasks=512 # 显式指定总逻辑核心数 # 也可以不写--ntasks,让Slurm根据节点和核心配置自动计算总任务数
2. 调整mpirun调用(无超订阅模式)
避免主进程动态派生,改用mpirun直接启动所有进程,适配MPI主从模式:
- 修改mpirun命令,直接启动511个进程:
mpirun --use-hwthread-cpus --np 511 python3 -u ./master.py
- 在
master.py中通过进程rank区分主从逻辑:
from mpi4py import MPI comm = MPI.COMM_WORLD rank = comm.Get_rank() if rank == 0: # 主进程逻辑 else: # 子进程逻辑
3. 解决超订阅模式下的UCX错误(若必须保留主进程派生)
如果必须保持主进程动态派生,需用--oversubscribe,同时通过环境变量禁用UCX的问题特性:
export UCX_TLS=rc,sm,self # 禁用引发错误的dc/ud传输层 export UCX_IB_DISABLE=1 # 或直接禁用IB传输,改用共享内存和TCP mpirun --use-hwthread-cpus --np 1 --oversubscribe python3 -u ./master.py 510
4. 验证插槽分配
在脚本中添加以下命令,确认Slurm分配的插槽数是否为512:
echo "Available slots: $SLURM_NTASKS"
内容的提问来源于stack exchange,提问作者jasmine