如何修改PU电压检测代码,排除0.0值仅识别0.01-0.8异常值?
解决方案
问题背景
现有Python代码扫描文档PU电压值时,会误将0.0空值判定为低于0.8PU的异常值,导致错误触发失败提示。需要修改代码排除0.0值,仅检测0.01至0.8之间的电压异常。
修改后的代码
timeForVoltageRecovery = 11.0 acceptableVoltagePU = 0.8 # 新增下限阈值,明确排除0.0空值 minimumVoltagePU = 0.01 for channel in data: if float(channel['time']) > timeForVoltageRecovery: isVoltageGood = True keys = channel.keys() keys.sort() volts = {} for key in keys: words = key.split(" ") if words[0] == "VOLT": volt_value = float(channel[key]) # 过滤掉0.0的空值,只保留有效电压数据 if volt_value != 0.0: volts[volt_value] = key.strip() voltsKeys = sorted(volts.keys()) # 取最低10个有效电压,若不足10个则取全部 check_count = min(10, len(voltsKeys)) for k in range(check_count): current_volt = voltsKeys[k] # 仅当电压处于0.01到0.8区间时,判定为异常 if minimumVoltagePU <= current_volt < acceptableVoltagePU: isVoltageGood = False if isVoltageGood: outfile.write("\nAt time %s, this scenario passed voltage recovery criteria of 0.8 PU!\n" % (channel['time'])) else: outfile.write("\n\t***** BAD: At Time %s, this scenario failed voltage recovery criteria of .8 PU :{ *****\n\n" % (channel['time'])) outfile.write("the lowest 10 voltages (excluding 0.0) in order are:\n") for k in range(check_count): outfile.write(f"\t{volts[voltsKeys[k]]} -> {voltsKeys[k]:.2f}\n") outfile.write("\n") break
关键修改点
- 新增下限阈值:定义
minimumVoltagePU = 0.01,明确异常值的范围边界 - 过滤空值:在收集电压数据时直接排除0.0值,避免后续无效判断
- 调整异常判定逻辑:仅当电压值满足
0.01 ≤ 电压 < 0.8时,才标记为异常 - 处理边界情况:当有效电压不足10个时,自动取全部有效数据进行检查和输出,避免索引越界错误
内容的提问来源于stack exchange,提问作者JMFcode
相关产品推荐